41 research outputs found

    Value of the SYNTAX score for periprocedural myocardial infarction according to WHO and the third universal definition of myocardial infarction:insights from the TWENTE trial

    Get PDF
    Aims: The SYNTAX score is a tool to quantify the complexity of coronary artery disease. We investigated the relation between the SYNTAX score and the occurrence of a periprocedural myocardial infarction (PMI) according to the historical definition of the World Health Organization (WHO) and the recently updated universal definition of MI. Methods and results: The SYNTAX score was calculated in 1,243 patients enrolled in TWENTE, a randomised trial which assessed second-generation drug-eluting stents. PMI was defined by the WHO definition and the third universal definition of MI. Patients were divided into tertiles of the SYNTAX score: ≀7 (n=430); >7 and <15 (n=390); ≄15 (n=423). PMI according to the WHO definition occurred more frequently in patients in the highest SYNTAX score tertile (7.3% vs. 3.1% vs. 1.6%, p<0.001) compared to the mid and lowest tertile. Similar findings were seen for universal PMI (9.9% vs. 7.7% vs. 3.7%, p<0.01). After multivariate analysis, SYNTAX score was a significant independent correlate of PMI for both definitions: the highest SYNTAX score tertile had an almost five times higher risk for WHO PMI, and a three times higher risk for universal PMI. Conclusions: In a broad patient population treated with second-generation DES, the SYNTAX score was able to stratify the risk of PM

    Safety of second-generation drug-eluting stents three years after randomised use in the TWENTE trial

    Get PDF
    Aims: To assess three-year clinical outcome following randomised use of the second-generation Resolute zotarolimus-eluting stent (ZES) and the XIENCE V everolimus-eluting stent (EES). For Resolute ZES and randomised use, outcome data ≄3 years are relatively scarce. Methods and results: The TWENTE trial examined 1,391 patients with stable angina or non-ST-elevation acute coronary syndromes, of whom 21.6% were diabetics, 70.1% had complex B2 or C lesions and 77.4% had “off-label” indications for DES use. Three-year follow-up data were obtained in 1,381 patients (99.3%; 10 withdrawals). Adverse clinical events were independently adjudicated. The primary endpoint target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction and clinically indicated target vessel revascularisation, was 12.1% for Resolute ZES and 13.4% for XIENCE V EES (p=0.50). Cardiac death rates were 1.9% vs. 3.5% (p=0.06); the other individual components of TVF also showed no significant between-group differences. The rates of definite-or-probable stent thrombosis (1.4% vs. 1.6%, p=0.82) and very late stent thrombosis (0.6% vs. 0.4%, p=1.0) did not differ between the groups. Conclusions: Three-year follow-up data of patients included in the randomised TWENTE trial demonstrated similar and sustained safety and efficacy of Resolute ZES and XIENCE V EE

    Impact of previous coronary artery bypass surgery on clinical outcome after percutaneous interventions with second generation drug-eluting stents in TWENTE trial and Non-Enrolled TWENTE registry

    Get PDF
    AbstractBackgroundPatients with previous coronary artery bypass grafting (CABG) who underwent percutaneous coronary intervention (PCI) have an increased repeat revascularization rate, but data on contemporary second-generation drug-eluting stents (DES) are scarce.MethodsWe evaluated 1-year clinical outcome following secondary revascularization by PCI in patients of the TWENTE trial and non-enrolled TWENTE registry, and compared patients with previous CABG versus patients without previous CABG.ResultsOf all 1709 consecutive patients, 202 (11.8%) had previously undergone CABG (on average 11.2±8.5years ago). CABG patients were older (68.5±9.4years vs. 64.1±10.7years, P<0.001) and more often had diabetes (28.7% vs. 20.9%, P=0.01) and previous PCI (40.1% vs. 19.8%, P<0.001) compared to patients without previous CABG. Nevertheless, a higher target vessel revascularization (TVR) rate following PCI in the CABG patients (9.4% vs. 2.3%, P<0.001) was the only significant difference in clinical outcome at 1-year follow-up (available for 99.6%). Among CABG patients, the TVR rate was significantly higher in patients treated for graft lesions (n=65; 95.4% in vein grafts) than in patients treated for native coronary lesions only (n=137) (18.5% vs. 5.1%, P=0.002). Among 1638 patients with PCI of native coronary lesions only, there was only a non-significant difference in TVR between patients with previous CABG versus patients without previous CABG (5.1% vs. 2.3%, P=0.08).ConclusionsPatients with previous CABG showed a favorable safety profile after PCI with second-generation DES. Nevertheless, their TVR rate was still much higher, driven by more repeat revascularizations after PCI of degenerated vein grafts. In native coronary lesions, there was no such difference

    TCT-251 Abnormal glucose metabolism and adverse event rates 12 months after treatment with contemporary drug-eluting stents:Insights from the BIO-RESORT Silent Diabetes study

    Get PDF
    BACKGROUND: Patients with abnormal glucose metabolism, including patients with undetected and thus untreated diabetes, may have higher event risks after percutaneous coronary intervention (PCI) with contemporary drug-eluting stents (DES). We assessed the prevalence and clinical impact of abnormal glucose metabolism in allcomer patients without previously known diabetes undergoing PCI. METHODS: The BIO-RESORT Silent Diabetes study, performed at Thoraxcentrum Twente, is a substudy of the randomized BIO-RESORT trial (NCT01674803). We performed an additional analysis identifying patients with an abnormal glucose metabolism by means of oral glucose tolerance testing (OGTT), and assessment of glycated hemoglobin A1c (HbA1c) with fasting plasma glucose (FPG) and clinical outcome at 12 months. RESULTS: Assessment of glucose metabolism revealed that of the 988 participants a total 330 (33.4%) patients had an abnormal metabolism, while 658 (66.6%) patients had a normal metabolism. Patients with abnormal glucose metabolism showed higher rates of the primary endpoint Target Vessel Failure (6.4% vs. 2.7%; p0.01), a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization. Multivariate analysis demonstrated that an abnormal glucose metabolism independently predicted adverse event risk (HR 2.2, 95%-CI:1.2-4.2). CONCLUSION: Abnormal glucose metabolism was detected in one out of three PCI all-comer patients and independently associated with a more than 2-fold higher event risk. Future intervention studies should determine whether meaningful benefits may accrue from routine glycaemia testing in such patients

    Comparison of eligible non-enrolled patients and the randomised TWENTE trial population treated with Resolute and XIENCE V drug-eluting stents

    Get PDF
    Aims: The TWENTE trial recently enrolled more than 80% of all eligible patients, who were randomised to zotarolimus-eluting Resolute or everolimus-eluting XIENCE V stents. In the present study, we investigated whether eligible, non-enrolled patients differed from the randomised TWENTE trial population in baseline characteristics and one-year outcome. Methods and results: Characteristics of 1,709 eligible patients were analysed. Independent external adjudication of clinical events was likewise performed for non-enrolled (n=318) and randomised patients (n=1,391). Non-enrolled and randomised patients did not differ in gender distribution, diabetes mellitus, and clinical presentation, but differed significantly in age and cardiovascular history. Nevertheless, clinical outcome after one year did not differ in the primary composite endpoint target-vessel failure (TVF; 9.8% vs. 8.1%; p=0.34), and its components cardiac death (1.6% vs. 1.2%; p=0.61), target vessel-related myocardial infarction (4.7% vs. 4.6%; p=0.92), and target-vessel revascularisation (3.8% vs. 3.0%; p=0.48). Previous bypass surgery predicted TVF in non-enrolled patients (p=0.001); removal of these patients resulted in identical TVF rates for non-enrolled and randomised patients (7.3% vs. 7.3%; p=0.99). Conclusions: Despite some differences in baseline characteristics, non-enrolled and randomised patients did not differ in one-year outcome, which was favourable for both populations and may be related to the drug-eluting stents used

    A Randomized Controlled Trial in Second-Generation Zotarolimus-Eluting Resolute Stents Versus Everolimus-Eluting Xience V Stents in Real-World Patients : The TWENTE Trial

    Get PDF
    ObjectivesThe aim of this study was to compare the safety and efficacy of Resolute zotarolimus-eluting stents (ZES) (Medtronic Cardiovascular, Santa Rosa, California) with Xience V everolimus-eluting stents (EES) (Abbott Vascular Devices, Santa Clara, California) at 1-year follow-up.BackgroundOnly 1 randomized trial previously compared these stents.MethodsThis investigator-initiated, patient-blinded, randomized noninferiority study had limited exclusion criteria (acute ST-segment elevation myocardial infarctions not eligible). Patients (n = 1,391; 81.4% of eligible population) were randomly assigned to ZES (n = 697) or EES (n = 694). Liberal use of stent post-dilation was encouraged. Cardiac biomarkers were systematically assessed. The primary endpoint was target vessel failure (TVF), a composite of cardiac death, myocardial infarction not clearly attributable to non-target vessels, and clinically indicated target-vessel revascularization. An external independent research organization performed clinical event adjudication (100% follow-up data available). Analysis was by intention-to-treat.ResultsAcute coronary syndromes were present in 52% and “off-label” feature in 77% of patients. Of the lesions, 70% were type B2/C; the post-dilation rate was very high (82%). In ZES and EES, TVF occurred in 8.2% and 8.1%, respectively (absolute risk-difference 0.1%; 95% confidence interval: −2.8% to 3.0%, pnoninferiority = 0.001). There was no significant between-group difference in TVF components. The definite-or-probable stent thrombosis rates were relatively low and similar for ZES and EES (0.9% and 1.2%, respectively, p = 0.59). Definite stent thrombosis rates were also low (0.58% and 0%, respectively, p = 0.12). In EES, probable stent thrombosis beyond day 8 was observed only in patients not adhering to dual antiplatelet therapy.ConclusionsResolute ZES were noninferior to Xience V EES in treating “real-world” patients with a vast majority of complex lesions and “off-label” indications for drug-eluting stents, which were implanted with liberal use of post-dilation. (The Real-World Endeavor Resolute Versus XIENCE V Drug-Eluting SteNt Study: Head-to-head Comparison of Clinical Outcome After Implantation of Second Generation Drug-eluting Stents in a Real World Scenario; NCT01066650

    Clinical Outcome Following Stringent Discontinuation of Dual Antiplatelet Therapy After 12 Months in Real-World Patients Treated With Second-Generation Zotarolimus-Eluting Resolute and Everolimus-Eluting Xience V Stents : 2-Year Follow-Up of the Randomized TWENTE Trial

    Get PDF
    Objectives The aim of this study was to assess the safety and efficacy of the implantation of Resolute zotarolimus-eluting stents (ZES) (Medtronic Inc., Santa Rosa, California) and Xience V everolimus-eluting stents (EES) (Abbott Vascular, Santa Clara, California) following strict discontinuation of dual antiplatelet therapy (DAPT) after 12 months. Background Only limited long-term follow-up data are available from head-to-head comparisons of second-generation drug-eluting stents. Methods The randomized TWENTE (The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente) trial is an investigator-initiated study performed in a population with many complex patients and lesions and only limited exclusion criteria. Patients were randomly assigned 1:1 to ZES (n = 697) or EES (n = 694). Results Two-year follow-up information was available on all patients. The rate of continuation of DAPT beyond 12 months was very low (5.4%). The primary endpoint of target vessel failure, a composite of cardiac death, target vessel–related myocardial infarction, and target vessel revascularization, did not differ between ZES and EES (10.8% vs. 11.6, p = 0.65), despite fewer target lesion revascularizations in patients with EES (2.6% vs. 4.9%, p = 0.03). The patient-oriented composite endpoint was similar (16.4% vs. 17.1%, p = 0.75). Two-year rates of definite or probable stent thrombosis were 1.2% and 1.4%, respectively (p = 0.63). Very late definite or probable stent thrombosis occurred only in 2 patients in each study arm (0.3% vs. 0.3%, p = 1.00). Conclusions After 2 years of follow-up and stringent discontinuation of DAPT beyond 12 months, Resolute ZES and Xience V EES showed similar results in terms of safety and efficacy for treating patients with a majority of complex lesions and off-label indications for drug-eluting stents. (The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twent

    TCT-47 Two-Year Clinical Outcome of the TWENTE Trial, a Randomized Controlled Trial Comparing Second-Generation Zotarolimus-Eluting Resolute Stents Versus Everolimus-Eluting Xience V Stents in Real-World Patients

    Get PDF
    Background: In the prospective, randomized TWENTE trial, the zotarolimus-eluting Resolute stent was at 1 year follow-up non-inferior to the everolimus-eluting Xience V stent for the primary endpoint target vessel failure. This composite endpoint consisted of cardiac death, clinically indicated target vessel revascularization, or target vessel-related myocardial infarction (MI). So far, few long-term data of prospective head-to-head comparisons between both DES have been reported. Methods: Patients requiring percutaneous coronary interventions (PCI) with DES implantation at Thoraxcentrum Twente in Enschede were randomization between Resolute (Medtronic Vascular, Santa Rosa, CA, USA) and Xience V (Abbott Vascular, Santa Clara, CA, USA) in a 1:1 fashion. Inclusion of all coronary or bypass graft lesions and all clinical settings was permitted except for primary PCI (i.e. acute ST-elevation myocardial infarction (STEMI) was an exclusion criterion). Both external monitoring and clinical event adjudication were performed by an independent external contract research organization (Cardialysis, Rotterdam, the Netherlands). Two year clinical follow-up was performed as indicated in the study protocol. Results: A total of 1,391 patients were enrolled in the TWENTE trial between June 2008 and August 2010. The study population comprised 21.6% diabetics with a vast majority of complex lesions and “off-label” indications for drug-eluting stents (77.4%). Patients presented with either stable angina (48.5%) or unstable angina/Non-STEMI (51.5%). Demographics, baseline angiographic and procedural data, and 2-year clinical follow-up data will be presented. This includes the primary endpoint of the study: Target vessel failure (TVF) at 2 year follow-up. Secondary endpoints include the individual components of the primary endpoint and the incidence of very late stent thrombosis. In addition, results of subgroup analyses will be reported. Conclusions: Results of pre-specified analyses of 2-year clinical outcome of the TWENTE trial will be presented at TCT 2012

    TCT-588 2-Year Clinical Outcome of the Randomized, Multicenter DUTCH PEERS (TWENTE II) Trial, Comparing Cobalt-Chromium Zotarolimus-Eluting Resolute Integrity Stents and Platinum-Chromium Everolimus-Eluting Promus Element Stents in “All-Comer” Patients

    Get PDF
    Background: The multicenter, prospective, randomized, single-blinded, investigator-initiated DUTCH PEERS (TWENTE II) “All Comers” Trial demonstrated at 1-year follow-up the non-inferiority of third-generation Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, CA) versus Promus Element everolimus-eluting stents (Boston Scientific, Natick, MA), based on a similar incidence of the primary endpoint target vessel failure (TVF), a composite of cardiac death, target vessel revascularization (TVR), or myocardial infarction (MI). No other follow-up data beyond 12 months have been published from a randomized head-to-head comparison of both stents. Methods: In 4 study centers in the Netherlands, 1,811 patients were 1:1 randomly assigned to treatment with one of both stents. Patients with any clinical syndrome, any lesion type, and any number of lesions or vessels to be treated were included. Study monitoring and clinical event adjudication were performed by two independent Dutch contract research organizations (Diagram, Zwolle, and Cardialysis, Rotterdam, respectively). Results: DUTCH PEERS examines an all-comer patient population that included 59% of patients with acute coronary syndromes (20% of all patients presented with an acute STEMI) and 66% of patients with complex target lesions. We will compare for both stent groups the 2-year incidence of TVF (primary endpoint) and various secondary endpoints, including individual components of the primary endpoint, the incidence of stent thrombosis, and other composite endpoints, such as target lesion failure, major adverse cardiac events, and the patient-oriented composite endpoint. In addition, we will report the outcome of patients with longitudinal stent deformation after discontinuation of dual anti-platelet therapy. Conclusions: Clinical outcome of the DUTCH PEERS trial at 2-year follow-up will be presented
    corecore